TítuloMagnetic probe system for equilibrium reconstruction of ETE tokamak plasmas
Ano2007
Data de Acesso18 maio 2024
Tipo SecundárioPRE CN
2. Contextualização
Autor1 Roussille, Andréia Vieira
2 Del Bosco, Edson
Grupo1 LAP-INPE-MCT-BR
2 LAP-INPE-MCT-BR
Afiliação1 Instituto Nacional de Pesquisas Espaciais (INPE)
2 Instituto Nacional de Pesquisas Espaciais (INPE)
Nome do EventoEncontro Brasileiro de Física dos Plasmas, 9.
Localização do EventoSão Pedro, SP
Data25-28 Nov.
Tipo TerciárioPoster
Histórico (UTC)2007-12-17 14:48:02 :: simone -> administrator ::
2012-10-24 00:13:53 :: administrator -> simone ::
2013-02-20 15:20:15 :: simone -> administrator :: 2007
2018-06-05 03:36:37 :: administrator -> marciana :: 2007
3. Conteúdo e estrutura
É a matriz ou uma cópia?é a matriz
Estágio do Conteúdoconcluido
Transferível1
Tipo do ConteúdoExternal Contribution
ResumoThe ETE (Experimento Tokamak Esf¶erico) of LAP/INPE is a spherical tokamak with aspect ratio parameter of 1.5. The machine was designed to produce plasma currents as high as 400kA with discharge duration of about 30ms. Presently, the capacitor bank energy available limits the maximum plasma current to about 60kA (10- 15ms). Magnetic probes are basic diagnostics for direct measurement of few relevant macroscopic parameters of tokamak plasmas, as for example total plasma current intensity, column displacement and position. Using a more sophisticate array of probes several internal parameters of the plasma column can be inferred from equilibrium reconstruction technique. A relatively complete set of magnetic probes was developed and installed inside the vacuum vessel of the ETE tokamak as the ¯rst step in order to implement the equilibrium reconstruction technique. This set of coils comprises: one complete Rogowski coil, four partial Rogowski coils, twenty six double magnetic probes (Br, Bz) distributed in four frames around the plasma column in a particular poloidal plane. The system is completed by one Rogowski coil and eleven total °ux coils installed outside the vacuum vessel. This paper describes in details the magnetic probes design, manufacture and calibration as well as presents the characteristics of a new data acquisition system based on PCI standard with 64 channels and the initial results obtained with the magnetic probe system.
ÁreaFISPLASMA
Arranjourlib.net > BDMCI > Fonds > Produção anterior à 2021 > LABAP > Magnetic probe system...
Conteúdo da Pasta docnão têm arquivos
Conteúdo da Pasta sourcenão têm arquivos
Conteúdo da Pasta agreementnão têm arquivos
4. Condições de acesso e uso
Idiomapt
Grupo de Usuáriosadministrator
simone
administrator
Visibilidadeshown
5. Fontes relacionadas
Unidades Imediatamente Superiores8JMKD3MGPCW/3ET2RFS
Acervo Hospedeirolcp.inpe.br/ignes/2004/02.12.18.39
cptec.inpe.br/walmeida/2003/04.25.17.12
6. Notas
Campos Vaziosarchivingpolicy archivist booktitle callnumber copyholder copyright creatorhistory descriptionlevel dissemination documentstage doi e-mailaddress edition editor electronicmailaddress format identifier isbn issn keywords label lineage mark mirrorrepository nextedition notes numberoffiles numberofvolumes orcid organization pages parameterlist parentrepositories previousedition previouslowerunit progress project publisher publisheraddress readergroup readpermission resumeid rightsholder schedulinginformation secondarydate secondarymark serieseditor session shorttitle size sponsor subject targetfile tertiarymark type url versiontype volume
7. Controle da descrição
e-Mail (login)marciana
atualizar 


Fechar